For Motor Production,Turn to Wind Automation!

 

Major in Motor Winding,Welding and Testing

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsCoil Winding Machine

Fan Motor Shaded Pole Stator Coil Needle Winding Machine Wind 4slots Per Time

Certification
Good quality Needle Winding Machine for sales
Good quality Needle Winding Machine for sales
We trust you and have very good references of you from our Shanghai colleagues

—— Olayo Delgado

We are very happy with the machines!

—— Efrain.Alvarado

I'm Online Chat Now

Fan Motor Shaded Pole Stator Coil Needle Winding Machine Wind 4slots Per Time

China Fan Motor Shaded Pole Stator Coil Needle Winding Machine Wind 4slots Per Time supplier
Fan Motor Shaded Pole Stator Coil Needle Winding Machine Wind 4slots Per Time supplier Fan Motor Shaded Pole Stator Coil Needle Winding Machine Wind 4slots Per Time supplier

Large Image :  Fan Motor Shaded Pole Stator Coil Needle Winding Machine Wind 4slots Per Time

Product Details:

Place of Origin: China
Brand Name: WIND AUTOMATION
Certification: CE
Model Number: WIND-1A-TSM
Detailed Product Description
Condition: New Certificate: Main Parts CE
Working Station: One Station Machine Color: White Or Accordingly To Customer Requirement
Shaded 4poles Motor Nozzles: 4 Nozzles Wind At Same Time Shaded Pole Motor,YZF Coil Winding Motor Type: Winder Most Suitable For Shaded Motor With 4poles
High Light:

motor coil winding machine

,

automatic coil winding machine

Fan Motor Shaded Pole Stator Coil Needle Winding Machine Wind 4slots Per Time WIND-1A-TSM

 

 

 

Application:

 

Shaded motor stator winding stepper motor winder is dedicated machine for wind 4poles stator,

 

Four pole stator winding machine WIND-1A-TSM wind 4slots per time for shaded motor

 

Four nozzles can get 1pc per time with high efficiency

 

 

Automatic stator needle winding machine application

 

Four poles shaded motor stator winding

 

 

Nozzle 4pcs

 

4poles wind at same time at 400rmp

 

 

4ploles stator needle winding

 

Dedicated machine for 4poles shaded motor

 

stator winding

 

 

 

 

Advantages:

 

1.Four needles work at same time,get 1pc wound shaded pole stator in one time, no need indexing, 

 

   fast and high efficiency

 

2. Four sets automatic clamp and cut wire device, wind shaded pole motor 4slots at same time,

 

    and cut wires automatically

 

3. Dedicated machine especially for shaded pole stator

 

 

 

Specification:

 

Wire diameter:0.08~1.00mm

 

Stator ID:15~65mm

 

Core length:7-90mm

 

Turns No.0-99999

 

Operation option: stepping,Auto

 

Stator poles: 4 poles

 

Air pressure:5~7kg/square centi-meter

 

Power:2KW, AC220V 50/60Hz

 

Dimension: 1550*900*1450mm

 

Weight: about 450kgs

 

 

 

Winder Configuration:

 

Big power Stepper motor

 

Mitsubishi PLC

 

Embedded human - machine interface

 

AIRTAC cylinder

 

 

 

Winding turns is related to the output current and torque,KV value.The smaller turns number of motor

 

stator, the higher the KV value, the lower the rated voltage, and the higher the rated current.

 

 

About KV value: even the same series of motors, there are several different versions of the KV value

 

parameters. Different KV values guide how to choose the electric harmonic battery pack. Here we will

 

explain more about how to choose a suitable KV value motor from the existing battery pack and electric

 

adjustment. For the same series of motors, the low KV version of the motor has a larger number of coil

 

turns, and the high KV value motor is the opposite. But as long as they have the same quality copper wire,

 

they will have the same maximum power, torque, efficiency and maximum speed under different voltage or

 

current. That is to say, under the same mass copper wire, the low KV value of the motor copper wire is

 

smaller, the number of turns is more, and the high KV value motor is the opposite. Moreover, the same

 

motor stator winding, can more the performance quality of copper wire is better (tankful rate). A chestnut,

 

a series of identical motors, with the same mass of copper, the electrical resistance of the 8 turn coil is 1

 

Omega, and the resistance of the 4 turn coil is 0.25 Omega. The difference of the resistance is 4 times.

 

 

Because the length of the 4 turns is doubled, the section area is doubled. It is known that when the

 

voltage of the 8 turns is two times that of the 4 turn motor, the input power is the same. And at this time

 

the copper loss P = I*I*R is exactly 4 and 4 times the resistance, so the copper loss is the same. That is,

 

both at the same time the hardness is the same, also known as the speed - torque characteristics are the

 

same. When the input voltage is the same, the difference of the input power is 4 times. At this time, the

 

torque of the 4 turn motor is much larger, and the speed of the 4 turn motor is twice as fast as that of the

 

8 turn, but at this time, the current of the 4 turn motor is 4 times of that of the 8 turn motor. In general, D

 

(tankful rate constant) change the number of turns, the hardness of the motor is constant, if the low KV

 

value of the input voltage of the motor is two times as high as the KV value, then the speed torque curve

 

of two motors should be the same. For the same load, the motor with low KV value is 1/2 higher than the

 

KV value, and because the resistance of the low KV value motor is 4 times higher than the KV value, so

 

the copper loss is the same, and the input power of the two is the same, so the efficiency of the two is the

 

same. Because the size of stator determines the rated power output of this series of motors, so the

 

advantage of low KV value motor is to output the corresponding stator rated power, but the required

 

current is low, but the required voltage is high. The advantage of the high KV - value motor is that it can

 

correspond to the rated power of the stator at a lower voltage, but at this point the current is higher. The

 

"low KV - value motor torque", which has been circulated, is based on the same current condition. The

 

same stator and tankful rate, low KV motor KV motor 4 turns and 8 turns are equivalent, the premise is the

 

input voltage of the former is half of the latter. Therefore, from the stator size of the motor to the KV value

 

of the motor, it is closely related to the parameters of the battery group and the electrical adjustment. In

 

view of the fixed technical parameters of the battery group, the corresponding motor should be selected

 

according to the parameters of the battery group. According to the following steps: A., such as 10 series

 

batteries, can probably output 500W, so the stator size of the motor is also about 500W of the rated

 

power.

 

 

 

Video:

Fan Motor Shaded Pole Stator Coil Needle Winding Machine Wind 4slots Per Time

 

 

 

Contact Details
Shanghai Wind Automation Equipment Co.,Ltd

Contact Person: Ms. Emily

Send your inquiry directly to us (0 / 3000)