Product Details:
|
Condition: | New | Certificate: | Main Parts CE |
---|---|---|---|
Working Station: | One Station | Machine Color: | White Or Accordingly To Customer Requirement |
Shaded 4poles Motor Nozzles: | 4 Nozzles Wind At Same Time Shaded Pole Motor,YZF | Coil Winding Motor Type: | Winder Most Suitable For Shaded Motor With 4poles |
Highlight: | motor coil winding machine,automatic coil winding machine |
Fan Motor Shaded Pole Stator Coil Needle Winding Machine Wind 4slots Per Time WIND-1A-TSM
Application:
Shaded motor stator winding stepper motor winder is dedicated machine for wind 4poles stator,
Four pole stator winding machine WIND-1A-TSM wind 4slots per time for shaded motor
Four nozzles can get 1pc per time with high efficiency
Automatic stator needle winding machine application |
Four poles shaded motor stator winding
|
Nozzle 4pcs |
4poles wind at same time at 400rmp
|
4ploles stator needle winding |
Dedicated machine for 4poles shaded motor
stator winding
|
Advantages:
1.Four needles work at same time,get 1pc wound shaded pole stator in one time, no need indexing,
fast and high efficiency
2. Four sets automatic clamp and cut wire device, wind shaded pole motor 4slots at same time,
and cut wires automatically
3. Dedicated machine especially for shaded pole stator
Specification:
Wire diameter:0.08~1.00mm
Stator ID:15~65mm
Core length:7-90mm
Turns No.0-99999
Operation option: stepping,Auto
Stator poles: 4 poles
Air pressure:5~7kg/square centi-meter
Power:2KW, AC220V 50/60Hz
Dimension: 1550*900*1450mm
Weight: about 450kgs
Winder Configuration:
Big power Stepper motor
Mitsubishi PLC
Embedded human - machine interface
AIRTAC cylinder
Winding turns is related to the output current and torque,KV value.The smaller turns number of motor
stator, the higher the KV value, the lower the rated voltage, and the higher the rated current.
About KV value: even the same series of motors, there are several different versions of the KV value
parameters. Different KV values guide how to choose the electric harmonic battery pack. Here we will
explain more about how to choose a suitable KV value motor from the existing battery pack and electric
adjustment. For the same series of motors, the low KV version of the motor has a larger number of coil
turns, and the high KV value motor is the opposite. But as long as they have the same quality copper wire,
they will have the same maximum power, torque, efficiency and maximum speed under different voltage or
current. That is to say, under the same mass copper wire, the low KV value of the motor copper wire is
smaller, the number of turns is more, and the high KV value motor is the opposite. Moreover, the same
motor stator winding, can more the performance quality of copper wire is better (tankful rate). A chestnut,
a series of identical motors, with the same mass of copper, the electrical resistance of the 8 turn coil is 1
Omega, and the resistance of the 4 turn coil is 0.25 Omega. The difference of the resistance is 4 times.
Because the length of the 4 turns is doubled, the section area is doubled. It is known that when the
voltage of the 8 turns is two times that of the 4 turn motor, the input power is the same. And at this time
the copper loss P = I*I*R is exactly 4 and 4 times the resistance, so the copper loss is the same. That is,
both at the same time the hardness is the same, also known as the speed - torque characteristics are the
same. When the input voltage is the same, the difference of the input power is 4 times. At this time, the
torque of the 4 turn motor is much larger, and the speed of the 4 turn motor is twice as fast as that of the
8 turn, but at this time, the current of the 4 turn motor is 4 times of that of the 8 turn motor. In general, D
(tankful rate constant) change the number of turns, the hardness of the motor is constant, if the low KV
value of the input voltage of the motor is two times as high as the KV value, then the speed torque curve
of two motors should be the same. For the same load, the motor with low KV value is 1/2 higher than the
KV value, and because the resistance of the low KV value motor is 4 times higher than the KV value, so
the copper loss is the same, and the input power of the two is the same, so the efficiency of the two is the
same. Because the size of stator determines the rated power output of this series of motors, so the
advantage of low KV value motor is to output the corresponding stator rated power, but the required
current is low, but the required voltage is high. The advantage of the high KV - value motor is that it can
correspond to the rated power of the stator at a lower voltage, but at this point the current is higher. The
"low KV - value motor torque", which has been circulated, is based on the same current condition. The
same stator and tankful rate, low KV motor KV motor 4 turns and 8 turns are equivalent, the premise is the
input voltage of the former is half of the latter. Therefore, from the stator size of the motor to the KV value
of the motor, it is closely related to the parameters of the battery group and the electrical adjustment. In
view of the fixed technical parameters of the battery group, the corresponding motor should be selected
according to the parameters of the battery group. According to the following steps: A., such as 10 series
batteries, can probably output 500W, so the stator size of the motor is also about 500W of the rated
power.
Video: